Back to Aurora Vision Studio website

You are here: Start » Filter Reference » Hardware Support » Z4Sight » Z4Sight_SetInputDebounceTime

Z4Sight_SetInputDebounceTime


Module: ThirdParty

Set input signal debounce.

Name Type Range Description
Input value inDeviceID Z4SightSystemAndDeviceIdentifier* Device identification.
Input value inInput Integer 0 - 63 Input signal.
Input value inDebounceTime Integer 0 - Amount of time the input signal is debounced (in ns).

Remarks

I/O device driver software

This filter is intended to cooperate with Zebra 4Sight devices, Zebra Indio I/O Cards and Zebra Concord Frame Grabbers using their vendor SDK. To be able to connect to the device, it is required to install Zebra AIL X SDK (Lite or Full version). Zebra 4Sight industrial PCs usually come with a preinstalled runtime license.

Add DLL path to system environment variable may be required.

Recommended Zebra AIL X SDK version for Aurora Vision Studio usage is V22H1 (10.60.0776).

Device identification

Device field can be used to specify the number (rank) of the target board of the specified system type. Device can be set to:

  • DEFAULT - Specifies the default board. The default board is set in the MILConfig utility.
  • DEVn - Specifies the device number (rank) of the board (where 0 <= n <=15).

System field can be used to specify the system type. System can be set to:

  • HOST - Specifies the default build-in system like IO in industrial PC.
  • CONCORD - Specifies the IO system from Concord framegrabber.
  • INDIO - Specifies the IO system from Concord IO Card.
Note: It is strongly recommended to set the appropriate System parameter to avoid communication issues.

Complexity Level

This filter is available on Advanced Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, Aurora Vision Studio Professional version.