You are here: Start » Filter Reference » Hardware Support » Hilscher » Hilscher_Channel_Open_Profinet
Module: | ThirdParty |
---|
Opens a Hilscher device channel connection.
Name | Type | Range | Description | |
---|---|---|---|---|
inBoardName | String* | |||
inChannelNumber | Integer | 0 - 10 | ||
inConfig | File* | Configuration file generated in SYCON.net (xxx.nxd) | ||
inNwid | File* | Configuration file generated in SYCON.net (xxx_nwid.nxd) | ||
inInputSignalConfiguration | HilscherSignalArray* | |||
inOutputSignalConfiguration | HilscherSignalArray* |
Remarks
Initial state
Opening an not configured channel sets all output slots to 0, configured channel data is left as it was.
Channel configuration
The channel is only configured with provided configuration files, if it is in a not configured state - no connection between card and master device (for example a PLC). If it is configured, the filter assumes proper operation, and leaves card configuration in existing condition.
Driver
- Windows driver (recommended 1.5.0.0) https://kb.hilscher.com/display/CIFXDRV/Versions+-+NXDRV-WIN
- SYCON.net for configuring slots, generating configuration files: https://kb.hilscher.com/display/SYCON/Version+History
For profinet: Firmware (recommended 3.13 series) https://kb.hilscher.com/display/PNS3V5/Version+History+-+V3.5+to+V3.x
Firmware needs to be uploaded to the card prior to opening any type of channel.
In case of failing to update the firmware, try to restart your computer.
Parallel execution
Complexity Level
This filter is available on Basic Complexity Level.
Disabled in Lite Edition
Filter Group
This filter is member of Hilscher_Channel_Open filter group.
See Also
For more information about using this filter please follow the link: Working with Hilscher device as a profinet slave.
Application Notes: Interfacing Hilscher cards (Profinet) to Aurora Vision Studio - document about connecting devices or establishing communication with Aurora Vision Studio.