Back to Aurora Vision Studio website

You are here: Start » Filter Reference » Camera Support » Ensenso » Ensenso_GrabPoint3DGrid_WithTimeout_Deprecated

Ensenso_GrabPoint3DGrid_WithTimeout_Deprecated


Module: ThirdParty

Captures a frame using Ensenso.

Name Type Range Description
Input value inDeviceID String* Device identifying number.
Input value inSettingsFile File* Initial grab parameters.
Input value inCalibrationFile File* Initial calibration file.
Input value inTimeout Integer 100 - 3600000 Maximum time to wait for frame in milliseconds.
Output value outGrid Point3DGrid? Captured Grid.
Output value outTimestamp Double? Captured Grid timestamp.

Remarks

Initial parameters

Initial parameters are only set during capture start. To change parameters either restart the stream, or use appropriate Set/Get filters.

Settings

To obtain settings from the camera:

  • From NxView Parameters window
    • Launch NxView
    • Open camera
    • Open Parameters window (menu Capture->Parameters...)
    • Adjust settings as wanted
    • Use Save... button
  • From NxTreeEdit application
    • Either:
      • Launch Aurora Vision Studio, add Ensenso_GrabPoint3DGrid_Deprecated filter, Run it
      • Launch NxView, open camera
    • Launch NxTreeEdit, connect to wanted instance
    • Adjust settings as wanted, either in NxView or NxTreeEdit
    • right click on /Cameras/BySerialNo/WantedSerialNumber and select Copy value as JSON string
    • save to a simple text file using an editor

The settings include all camera parameters, including Link, Calibration and Parameters The saved file can be then used in inCalibrationFile and inSettingsFile arguments.

Camera identification

When there is only one Ensenso camera connected, the field inDeviceID can be set to Auto. In this situation, the first available camera will be used.

inDeviceID can be used to pick one of multiple cameras connected to the computer. inDeviceID should be set to camera ID.

Camera driver software

This filter is intended to cooperate with cameras using their vendor's SDK. In order to connect with the camera, it is required to install Ensenso SDK software, and uEye driver (same as in IDS camera filters)

Ensenso SDK and uEye driver can be downloaded from the following website: https://www.optonic.com/en/support/download/ensenso-sdk/

Recommended Ensenso SDK version for Aurora Vision Studio usage is 3.5.1419 and uEye driver 4.96.1.

Parallel execution

This filter cannot be placed in multiple Workers.

Complexity Level

This filter is available on Basic Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, Aurora Vision Studio Professional version.