Back to Aurora Vision Studio website
You are here: Start » Filter Reference » Hardware Support » Aurora Imaging Library » AILSystem_Modbus_Client_ReadDiscreteInputs
AILSystem_Modbus_Client_ReadDiscreteInputs
| Module: | ThirdParty |
|---|
Reads the discrete input data table of a remote Modbus server.
| Name | Type | Range | Description | |
|---|---|---|---|---|
![]() |
inDeviceID | AILSystemAndDeviceIdentifier* | Device identification. | |
![]() |
inInstanceName | String* | Instance name of a given Industrial Communication protocol set in the MILConfig utility. | |
![]() |
inServerId | Integer | 0 - 255 | Identifier of the remote Modbus server. |
![]() |
inServerAddress | String* | IPv4 address of the remote Modbus server. Not needed when the server is declared in the Aurora Imaging Configurator utility. | |
![]() |
inOffset | Integer | 0 - 65535 | Offset from which to start reading the data in the specified data table. |
![]() |
inCount | Integer | 1 - 2000 | Amount of the data to read. |
![]() |
outValues | BoolArray | Received values. | |
Complexity Level
This filter is available on Advanced Complexity Level.
Disabled in Lite Edition
This filter is disabled in Lite Edition. It is available only in full, Aurora Vision Studio Professional version.

Advanced