Back to Aurora Vision Studio website

You are here: Start » Filter Reference » Hardware Support » Aurora Imaging Library » AILSystem_Modbus_Client_ReadDiscreteInputs

AILSystem_Modbus_Client_ReadDiscreteInputs


Module: ThirdParty

Reads the discrete input data table of a remote Modbus server.

Name Type Range Description
Input value inDeviceID AILSystemAndDeviceIdentifier* Device identification.
Input value inInstanceName String* Instance name of a given Industrial Communication protocol set in the MILConfig utility.
Input value inServerId Integer 0 - 255 Identifier of the remote Modbus server.
Input value inServerAddress String* IPv4 address of the remote Modbus server. Not needed when the server is declared in the Aurora Imaging Configurator utility.
Input value inOffset Integer 0 - 65535 Offset from which to start reading the data in the specified data table.
Input value inCount Integer 1 - 2000 Amount of the data to read.
Output value outValues BoolArray Received values.

Complexity Level

This filter is available on Advanced Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, Aurora Vision Studio Professional version.