Back to Aurora Vision Library website

You are here: Start » Function Reference » System » Modbus TCP » ModbusTCP_ReadMultipleRegisters_AsByteBuffer

ModbusTCP_ReadMultipleRegisters_AsByteBuffer


Header: STD.h
Namespace: avl
Module: FoundationLite

Function Code 03. Reads the contents of a contiguous block of holding registers in a remote device

Syntax

void avl::ModbusTCP_ReadMultipleRegisters_AsByteBuffer
(
	const avl::SocketId& inSocket,
	const atl::Optional<int>& inTimeout,
	int inUnitID,
	int inStartingAddress,
	int inCount,
	avl::ByteBuffer& outData
)

Parameters

Name Type Range Default Description
Input value inSocket const SocketId& Connected socket ID on port 502.
Input value inTimeout const Optional<int>& 10 - NIL Timeout in milliseconds, block if not specified.
Input value inUnitID int 0 - 255 1 Default is 1.
Input value inStartingAddress int 0 - 65535 The address of the first holding register.
Input value inCount int 1 - 125 1 Number of registers to read. Each register is 2 Bytes in size.
Output value outData ByteBuffer& Received register values.

See Also