ModbusTCP_ReadDiscreteInputs


Header: STD.h
Namespace: avl
Module: FoundationLite

Function Code 02. Reads contiguous status of discrete inputs in a remote device

Syntax

void avl::ModbusTCP_ReadDiscreteInputs
(
	const avl::SocketId& inSocket,
	const atl::Optional<int>& inTimeout,
	int inUnitID,
	int inStartingAddress,
	int inBitCount,
	atl::Array<bool>& outBits
)

Parameters

Name Type Range Default Description
Input value inSocket const SocketId& Connected socket ID on port 502.
Input value inTimeout const Optional<int>& 10 - NIL Timeout in milliseconds, block if not specified.
Input value inUnitID int 0 - 255 1 Default is 1.
Input value inStartingAddress int 0 - 65535 The address of the first input.
Input value inBitCount int 1 - 2000 1 Requested number of bits.
Output value outBits Array<bool>& Response.