Back to Aurora Vision Library website

You are here: Start » Function Reference » Hardware Support » Hilscher » Hilscher_Channel_SlotWrite_SInt8

Hilscher_Channel_SlotWrite_SInt8


Header: ThirdPartySdk.h
Namespace: avl
Module: ThirdParty

Sends generic packet that can be filled with any data through Hilscher device.

Syntax

void avl::Hilscher_Channel_SlotWrite_SInt8
(
	avl::Hilscher_State& ioState,
	const atl::Optional<atl::String>& inBoardName,
	const int inChannelNumber,
	const int inSlot,
	const int inData
)

Parameters

Name Type Range Default Description
Input will be modified ioState Hilscher_State& Object used to maintain state of the function.
Input value inBoardName const Optional<String>& NIL
Input value inChannelNumber const int 0 - 10
Input value inSlot const int 0 - 1000
Input value inData const int -128 - 127

Remarks

Driver

For profinet: Firmware (recommended 3.13 series) https://kb.hilscher.com/display/PNS3V5/Version+History+-+V3.5+to+V3.x

Firmware needs to be uploaded to the card prior to opening any type of channel.
In case of failing to update the firmware, try to restart your computer.

inSlot
Slot as configured in Profinet/Hilscher software
Data direction
Slot direction is from the application perspective, different than in SYCON software.
IN: in SYCON.net is marked as output
OUT: in SYCON.net is marked as input
Data endianness
Remember to check endianness on controller and device sides, most controllers will use big endian. Data written to the card will be converted by default to network order. (to big endian)