Back to Aurora Vision Library Lite website
You are here: Start » Hardware Support » XSight » XSight_SetOutputPulseTriggered
XSight_SetOutputPulseTriggered
Header: | ThirdPartySdk.h |
---|---|
Namespace: | avl |
Sets output pulse triggered by input port.
Syntax
void avl::XSight_SetOutputPulseTriggered ( XSight_State& ioState, atl::Optional<int> inDeviceIndex, int inPort, int inDelay, int inPulseWidth, int inTriggerPort, avl::XSightTriggerEdge::Type inTriggerEdge )
Parameters
Name | Type | Range | Default | Description | |
---|---|---|---|---|---|
ioState | XSight_State& | Object used to maintain state of the function. | |||
inDeviceIndex | Optional<int> | 0 - | NIL | Device identifying number. | |
inPort | int | 1 - 16 | 1 | IO port description number. | |
inDelay | int | 0 - | 0 | Output delay in us unit. | |
inPulseWidth | int | 1 - | 100 | Pulse width in us unit. | |
inTriggerPort | int | 1 - 16 | 1 | Input port description number. | |
inTriggerEdge | XSightTriggerEdge::Type |
Remarks
Device identification
inDeviceIndex can be used to pick one of multiple devices connected to the computer. inDeviceIndex can be set to:
- Device Index - X-Sight I/O device identifying internal index.
I/O device driver software
This filter is intended to cooperate with a device using its vendor SDK. To be able to connect to a device, it is required to install X-Sight SDK.
Add DLL path to system environment variable is required.
Recommended Runtime version for Aurora Vision Studio usage is 1.0.0.
Invoking I/O port filters who force specifics behaviour (for example, set output level) may also change I/O mode to fitted.