Matrox_Modbus_ReadInputRegisters_sint16
Header: | ThirdPartySdk.h |
---|---|
Namespace: | avl |
Reads the input register data table as signed 16-bit integers.
Syntax
void avl::Matrox_Modbus_ReadInputRegisters_sint16 ( Matrox_State& ioState, atl::Optional<const avl::MatroxSystemAndDeviceIdentifier&> inDeviceID, const atl::Optional<atl::String>& inInstanceName, int inOffset, int inCount, atl::Array<int>& outValues )
Parameters
Name | Type | Range | Default | Description | |
---|---|---|---|---|---|
ioState | Matrox_State& | Object used to maintain state of the function. | |||
inDeviceID | Optional<const MatroxSystemAndDeviceIdentifier&> | NIL | Device identification. | ||
inInstanceName | const Optional<String>& | NIL | Instance name of a given Industrial Communication protocol set in the MILConfig utility. | ||
inOffset | int | 0 - 65535 | Offset from which to start reading the data in the specified data table. | ||
inCount | int | 1 - 125 | Amount of the data to read. | ||
outValues | Array<int>& | Received values. |