Back to Aurora Vision Library Lite website
You are here: Start » Hardware Support » XSight » XSight_GetPWMState
XSight_GetPWMState
Header: | ThirdPartySdk.h |
---|---|
Namespace: | avl |
Gets PWM state.
Syntax
void avl::XSight_GetPWMState ( XSight_State& ioState, atl::Optional<int> inDeviceIndex, int inChannel, bool& outEnable )
Parameters
Name | Type | Range | Default | Description | |
---|---|---|---|---|---|
ioState | XSight_State& | Object used to maintain state of the function. | |||
inDeviceIndex | Optional<int> | 0 - | NIL | Device identifying number | |
inChannel | int | 1 - 6 | 1 | PWM channel description number. | |
outEnable | bool& |
Remarks
Device identification
inDeviceIndex can be used to pick one of multiple devices connected to the computer. inDeviceIndex can be set to:
- Device Index - X-Sight I/O device identifying internal index.
I/O device driver software
This filter is intended to cooperate with a device using its vendor SDK. To be able to connect to a device, it is required to install X-Sight SDK.
Add DLL path to system environment variable is required.
Recommended Runtime version for Aurora Vision Studio usage is 1.0.0.
Invoking I/O port filters who force specifics behaviour (for example, set output level) may also change I/O mode to fitted.