You are here: Start » AVL.NET » AVS.CalibrateCamera_Telecentric Method

AVS.CalibrateCamera_Telecentric Method

Finds the telecentric camera intrinsic parameters from calibration grids.

Namespace:AvlNet
Assembly:AVL.NET.dll

Syntax

public static void CalibrateCamera_Telecentric
(
	IList<IList<AvlNet.AnnotatedPoint2D>> inImageGrids,
	float inGridSpacing,
	int inImageWidth,
	int inImageHeight,
	AvlNet.LensDistortionModelType inDistortionType,
	float inImagePointsStandardDeviation,
	AvlNet.TelecentricCameraModel outCameraModel
)

Parameters

Name Type Range Default Description
inImageGridsSystem.Collections.Generic.IList<System.Collections.Generic.IList<AvlNet.AnnotatedPoint2D>>For each view, the annotated calibration grid.
inGridSpacingfloat<0.000001f, INF>Real-world distance between adjacent grid points.
inImageWidthint<1, INF>Image width, used for initial estimation of principal point.
inImageHeightint<1, INF>Image height, used for initial estimation of principal point.
inDistortionTypeAvlNet.LensDistortionModelTypePolynomialWithThinPrismLens distortion model. Default value: PolynomialWithThinPrism.
inImagePointsStandardDeviationfloat<0.0f, INF>0.1fAssumed uncertainty of inImagePoints. Used for robust optimization and outCameraModelStdDev estimation. Default value: 0.1f.
outCameraModelAvlNet.TelecentricCameraModel

Function Overrides

See also