Back to Aurora Vision Studio website
You are here: Start » Filter Reference » Hardware Support » Z4Sight » Z4Sight_RegisterPulse_Deprecated
Module: | ThirdParty |
---|
Registers a pulse in a command list.
Name | Type | Range | Description | |
---|---|---|---|---|
inDeviceID | Z4SightDeviceID* | Device identification number. | ||
inCommandList | Integer | 1 - 2 | I/O command list. | |
inCommandBit | Integer | 0 - 7 | Bit of the command list. | |
inPulseType | Z4SightPulseType | Type of the pulse to register. | ||
inReferenceMoment | Long* | Value of counter for which the command is to be registered (in seconds or counts). | ||
inDelay | Real | 0.0 - | Delay from the specified counter value. | |
inDuration | Real | 0.0 - | Duration of the pulse. |
Complexity Level
This filter is available on Advanced Complexity Level.
Disabled in Lite Edition
This filter is disabled in Lite Edition. It is available only in full, Aurora Vision Studio Professional version.