OptoEngineeringHRAS_COE71_GrabImage


Module: ThirdParty

Captures an image using COE-71 Opto Engineering device.

Name Type Range Description
inDeviceID String* Device identifying number
inInputQueueSize Integer 1 - Capacity of output frames queue
inBitDepth OptoEngineeringBitDepth Number of pixel bits
inStrobePolarity OptoEngineering_COE71_StrobePolarity* Polarity of strobe output signal
inTriggerMode OptoEngineering_COE71_TriggerMode Device triggering mode
inDigitalGain Real* 0.0 - 16.0 Gain of source image in device raw unit
inDigitalOffset Integer* -32767 - 32767 Offset of source image in device raw unit
inExposureTime Integer* 1 - 65535 Camera frame exposition time
inExposureUnit OptoEngineeringExposureUnit Camera frame exposition time unit
outImage Image Captured frame

Remarks

Camera driver software

This filter is intended to cooperate with a camera using its vendor SDK. To be able to connect to a camera, it is required to install eBUS software with camera dedicated drivers.

eBUS SDK can be downloaded from the following website: https://supportcenter.pleora.com/s/topic/0TO340000004X6dGAE/ebus-sdk?tabset-0c866=2&tabset-25adb=81d66 (registration may be required).

Recommended eBUS SDK version for Adaptive Vision Studio usage is 5.1.10.4642.

Add DLL path to system environment variable may be required.

Camera identification

When there is only one camera connected to a computer, field inDeviceID can be set to Auto. In this case, first available camera will be found and connected.

inDeviceID field can be used to pick one of multiple cameras connected to computer. DeviceID can be set to:

  • Device unique id number - should be specified on device casing.
Camera parameters

To change other and more advanced internal camera parameters use configuration tool "Camera Control Application" available from the following website: https://www.opto-e.com/products/coe-area-scan#Downloads (registration may be required).

Other device settings can be changed also with eBUs Player available from the following website: https://www.pleora.com/products/ebus-sdk/ (registration may be required).

Supported devices

This filter support only COE HR AS 50, 71 and 29 series with USB interface. COE-71 devices have dedicated support.

Multithreaded environment

This function is not guaranteed to be thread-safe. When used in multithreaded environment, it has to be manually synchronized.

Complexity Level

This filter is available on Basic Complexity Level.

Filter Group

This filter is member of OptoEngineeringHRAS_COE71_GrabImage filter group.

See Also