Function Code 04
| Name | Type | Range | Description | |
|---|---|---|---|---|
![]() |
inSocket | SocketId | Connected socket ID on port 502. | |
![]() |
inTimeout | Integer* | 100 - ![]() |
Timeout in milliseconds, block if not specified. |
![]() |
inUnitID | Integer | 0 - 255 | Default is 1 |
![]() |
inReferenceNumber | Integer | 0 - 65535 | Start Address |
![]() |
inCount | Integer | 1 - 125 | |
![]() |
inInputDataFormat | ModbusDataFormat | ||
![]() |
outIntegerValues | IntegerArray | Received integer values | |
Complexity Level
This filter is available on Basic Complexity Level.
Disabled in Lite Edition
This filter is disabled in Lite Edition. It is available only in full, Adaptive Vision Studio Professional version.
Filter Group
This filters is member of ModbusTCP_Read filter group.