ModbusTCP_ForceMultipleCoils


Function Code 15

Name Type Range Description
inSocket SocketId Connected socket ID on port 502.
inTimeout Integer* 100 - Timeout in milliseconds, block if not specified.
inUnitID Integer 0 - 255 Default is 1
inReferenceNumber Integer 0 - 65535 Start Address
inStatuses BoolArray

Errors

This filter can throw an exception to report error. Read how to deal with errors here: Error Handling

Error type Description
DomainError Size of statuses array should be between 1 and 800.

Complexity Level

This filter is available on Basic Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, Adaptive Vision Studio Professional version.