ModbusTCP_WriteSingleRegister


Function Code 06

Syntax

void avl::ModbusTCP_WriteSingleRegister
(
	const atl::SocketId& inSocket,
	const atl::Optional<int>& inTimeout,
	int inUnitID,
	int inReferenceNumber,
	int inIntegerValue,
	avl::ModbusDataFormat::Type inDataFormat
)

Parameters

Name Type Range Default Description
inSocket const SocketId& Connected socket ID on port 502.
inTimeout const Optional<int>& 100 - NIL Timeout in milliseconds, block if not specified.
inUnitID int 0 - 255 1 Default is 1
inReferenceNumber int 0 - 65535 Start Address
inIntegerValue int Value to send
inDataFormat ModbusDataFormat::Type