ModbusTCP_WriteMultipleRealRegisters


Function Code 16

Syntax

void avl::ModbusTCP_WriteMultipleRealRegisters
(
	const atl::SocketId& inSocket,
	const atl::Optional<int>& inTimeout,
	int inUnitID,
	int inReferenceNumber,
	const atl::Array<atl::real>& inRealValues
)

Parameters

Name Type Range Default Description
inSocket const SocketId& Connected socket ID on port 502.
inTimeout const Optional<int>& 100 - NIL Timeout in milliseconds, block if not specified.
inUnitID int 0 - 255 1 Default is 1
inReferenceNumber int 0 - 65535 Start Address
inRealValues const Array<real>& Real values to set