Back to Adaptive Vision Studio website

You are here: Start » Filter Reference » Modbus TCP » ModbusTCP_ForceMultipleCoils

ModbusTCP_ForceMultipleCoils


Function Code 15. Force each coil in a sequence of coils to either ON or OFF in a remote device

Name Type Range Description
inSocket SocketId Connected socket ID on port 502.
inTimeout Integer* 10 - Timeout in milliseconds, block if not specified.
inUnitID Integer 0 - 255 Default is 1.
inStartingAddress Integer 0 - 65535 The address of the first coil.
inStatuses BoolArray

Remarks

User manual

For more informations about using this filters please follow the link: Communication with Modbus TCP devices.

Errors

This filter can throw an exception to report error. Read how to deal with errors in Error Handling.

List of possible exceptions:

Error type Description
DomainError Size of statuses array should be between 1 and 1968.

Complexity Level

This filter is available on Basic Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, Adaptive Vision Studio Professional version.

Filter Group

This filter is member of ModbusTCP_Write filter group.

See Also

  • ModbusTCP_WriteCoil – Function Code 05. Write a single output to either ON or OFF in a remote device