Back to Adaptive Vision Studio website

You are here: Start » Filter Reference » Imago Technologies » VisionBox_StrobeSetFixedCurrent

VisionBox_StrobeSetFixedCurrent


Sets strobes fixed current

Name Type Description
inStrobeUnit Integer Number of strobe device to use
inSupplyVoltage Integer Supply voltage used for the strobe output
inLoadVoltage Integer The voltage across the load when the output current is equal to inCurrent
inMaxOnTime Integer Maximum allowed on-time in us
inMinOffTime Integer Minimum allowed off-time in us
inCurrent Integer Output current in mA
outResult Integer Minimum allowed off-time

Description

This filter is simple wrapper over Strobe::SetFixedCurrent SDK function. Refer to AGE-X SDK to see how to use this function properly.

Remarks

Precondition for use of VisionBox filters is to have Imago Technologies AGE-X SKD installed on target computer. AGE-X SDK provides filters with necessary libraries (DLL files) and drivers. After installation of AGE-X SDK, system restart may be required.

Recommended AGE-X SDK version for Adaptive Vision Studio usage is 1.6.8.0.

Multithreaded environment

This function is not guaranteed to be thread-safe. When used in multithreaded environment, it has to be manually synchronized.

Complexity Level

This filter is available on Basic Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, Adaptive Vision Studio Professional version.