Hilscher_Channel_SlotWrite_SInt16


Sends generic packet that can be filled with any data through Hilscher device.

Name Type Range Description
inBoardName String*
inChannelNumber Integer 0 - 10
inSlot Integer 0 - 1000
inDataEndianness DataEndianness
inData Integer -32768 - 32767

Remarks

Driver

For profinet: Firmware (recommended 3.13 series) https://kb.hilscher.com/display/PNS3V5/Version+History+-+V3.5+to+V3.x

Firmware needs to be uploaded to the card prior to opening any type of channel.
In case of failing to update the firmware, try to restart your computer.

inSlot
Slot as configured in Profinet/Hilscher software
Data direction
Slot direction is from the application perspective, different than in SYCON software.
IN: in SYCON.net is marked as output
OUT: in SYCON.net is marked as input
Data endianness
Remember to check endianness on controller and device sides, most controllers will use big endian. Data written to the card will be converted by default to network order. (to big endian)
Data read from the card will be converted to native byte order. (by default from big endian)

Multithreaded environment

This function is not guaranteed to be thread-safe. When used in multithreaded environment, it has to be manually synchronized.

Complexity Level

This filter is available on Basic Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, Adaptive Vision Studio Professional version.

Filter Group

This filter is member of Hilscher_Channel_SlotWrite filter group.