Ensenso_SetParameter_Int_Deprecated


Header:ThirdPartySdk.h
Namespace:avl

Set int parameter

Syntax

void avl::Ensenso_SetParameter_Int_Deprecated
(
	Ensenso_State& ioState,
	const atl::Optional<atl::String> inDeviceID,
	const atl::String& inPath,
	const bool inGlobal,
	const int inValue
)

Parameters

Name Type Default Description
ioState Ensenso_State& Object used to maintain state of the function.
inDeviceID const Optional<String> NIL Device identifying number
inPath const String& Configuration path, relative
inGlobal const bool False true: Path is relative to global configuration root; false: relative to camera configuration
inValue const int

Examples

Configuration tree
Configuration paths are relative to root or camera tree.

for example path

Sensor/Temperature
with
inGlobal = false
will give read only access to currently opened camera sensor temperature (double)

path

Parameters/Capture/PixelClock
with
inGlobal = false
will give access to camera pixel clock

Remarks

Camera identification

When there is only one Ensenso camera connected, the field inDeviceID can be set to Auto. In this situation, the first available camera will be used.

inDeviceID can be used to pick one of multiple cameras connected to the computer. inDeviceID should be set to camera ID.

Camera driver software

This filter is intended to cooperate with cameras using their vendor's SDK. In order to connect with the camera, it is required to install Ensenso SDK software, and uEye driver (same as in IDS camera filters)

Ensenso SDK can be downloaded from the following website: https://www.ensenso.com/support/sdk-download/

uEye driver can be downloaded from the following website: https://en.ids-imaging.com/download-ueye.html

Recommended Ensenso SDK version for Adaptive Vision Studio usage is 2.2 and uEye driver 4.90.

Multithreaded environment

This function is not guaranteed to be thread-safe. When used in multithreaded environment, it has to be manually synchronized.