Writes the holding register data table of a remote Modbus server as 32-bit floating point numbers.
Syntax
C++
Python
def AILSystem_Modbus_Client_WriteHoldingRegisters_float32( state: AILSystem_State, inServerId: int, inValues: list[float], /, *, inDeviceID: AILSystemAndDeviceIdentifier | None = None, inInstanceName: str | None = None, inServerAddress: str | None = None, inOffset: int = 0, inUseLittleEndian: bool = False ) -> None
Parameters
| Name | Type | Range | Default | Description | |
|---|---|---|---|---|---|
![]() |
ioState | AILSystem_State | |||
![]() |
inDeviceID | AILSystemAndDeviceIdentifier | None | None | Device identification. | |
![]() |
inInstanceName | str | None | None | Instance name of a given Industrial Communication protocol set in the MILConfig utility. | |
![]() |
inServerId | int | 0 - 255 | Identifier of the remote Modbus server. | |
![]() |
inServerAddress | str | None | None | IPv4 address of the remote Modbus server. Not needed when the server is declared in the Aurora Imaging Configurator utility. | |
![]() |
inOffset | int | 0 - 65534 | 0 | Offset to which to start writing the data in the specified data table. |
![]() |
inUseLittleEndian | bool | False | Use little endian order for words in the registers. | |
![]() |
inValues | list[float] | Values to write. |